AUDIT-C12: usb_data_interface_ft2232h had a misleading single-buffer comment that overstated the timing slack and referenced a frame_ack_toggle CDC that was never implemented. Re-verified actual numbers: at 178 fps the slack is 1.14 ms (20%), not "much shorter than gap". No data corruption today (write order matches read order, addresses don't collide), but frame_complete firing while WR_FSM is still draining the previous frame causes silent frame drops via the missed frame_ready_toggle edge. Fix is instrumentation, not architectural rework: add wr_done_toggle (ft_clk -> clk CDC) on WR_DONE -> WR_IDLE, track frame_pending in clk domain, count drops in 7-bit saturating frame_drop_count, surface in unused upper 7 bits of status_words[5]. Host now has visibility into the failure mode if margin ever shrinks (faster frame rate or USB bandwidth shortfall). Replaced misleading comment with corrected timing breakdown. AUDIT-S22: cfar_ca emits one detection per 3 cycles (THR/MUL/CMP); the detection RMW takes 3 cycles. Match by construction today, fragile against any CFAR speedup. Added a header comment in cfar_ca.v documenting the dependency, and a SIMULATION-only assertion in usb_data_interface_ft2232h.v that fires [ASSERT FAIL] AUDIT-S22 if cfar_valid arrives while RMW busy. Catches silent-drop regressions in the test suite. Verification: new tb_ft2232h_frame_drop.v with 5 scenarios (no drops / stalled drops / multi-drop / recovery / saturation at 127) - 10/10 PASS. Quick regression 31/31 PASS (was 30/30; +1 new test, 0 regressions).