Stage-7 ADC chain audit. radar_receiver_final.v's
adc_overrange_sticky_400m had no clear path other than full system
reset_n — once latched, the only way to acknowledge the AD9484
overrange flag was a reboot. The DDC's analogous diagnostic flags
(cdc_cic_fir_overrun_sticky, mixer_saturation) already clear on the
DDC's `reset_monitors` port; the OR sticky in the receiver wrapper
was the lone outlier.

Introduce a shared `clear_monitors_pulse` wire at the receiver scope
and route it both to the OR sticky's clear branch and to the DDC's
`reset_monitors` port (replacing the literal `1'b0`). Today the
wire is tied 1'b0, preserving the prior reset_n-only behaviour bit-
for-bit. When a future host opcode for "clear diagnostic stickies"
lands, both the receiver-level OR sticky and the DDC's internal
sticky flags clear from the same pulse — no per-flag re-plumbing.

Local FPGA regression 36/1/6 unchanged (1 FAIL = pre-existing T-6
drift, deferred PR-M.4).